Ingersoll Rand's standard pressure centrifugal compressors offer reliable air that meets flow requirements for a variety of critical applications.
Ranges:
Capacity Range: From 25 To 800 m3/min
Pressure Range: From 2 To 10 Bar (A)
Capacity Range: From 45 To 850 m3/min "Standard Pressure"
Pressure Range: From 3 To 10.3 Bar (g)
Capacity Range: From 37 To 255 m3/min "Low Pressure"
Pressure Range: From 0.4 To 2.1 Bar (g)
Capacity Range: From 50 To 283 m3/min "High Pressure"
Pressure Range: From 10.3 To 42 Bar (g)
Engineered Built as customer required
CV1/C400 Easy Line – Description
Advanced centrifugal technology for 100% oil-free air
IP23, 400 V / 3 ph / 50 Hz high efficiency flanged motor with windings
protection by PTC thermistors and trip function on control panel
(Ingersoll Rand brand or choice)
State-of-the-art control system with CMC microcontroller and integrated
star-delta starter
Constant pressure control with Modulate or Autodual regulation
High efficiency single stage inlet air filter with differential pressure switch
for dirty inlet air filter
- By-pass recirculation piping
- Differential pressure switch for dirty oil filter
- Low cooling water flow switch
- Oil cooler designed for a max. cooling water temperature up to 40°C
- Techtrol Gold (shipped loose)
- Auto hot start function including running unloaded shutdown timer, cooling water solenoid valve control 1 (contact voltage 110 V/AC) with remote indication of: compressor ready, alarm/trip, running
C700 Easy Line – Description
- Advanced centrifugal technology for 100% oil-free air.
- IP23 / 3 ph / 50 Hz high efficiency flanged motor (Ingersoll Rand brand) with motor windings protection by PT100 thermoresistances, with temperature reading and alarm/trip.
- State-of-the-art control system with CMC microcontroller.
- Integrated star-delta starter (for 400 V motors only).
- Constant pressure control with Modulate or Autodual regulation.
- Integrated Inlet Guide Vanes.
- High efficiency inlet air filter with integral by-pass silencer (shipped loose on unenclosed models, mounted on enclosed models) and differential pressure switch for dirty inlet air filter.
- Differential pressure switch for dirty inlet oil filter.
- Low cooling water flow switch.
- Oil cooler designed for a max. cooling water temperature up to 40°C.
- Techtrol Gold (shipped loose).
- Auto hot start function including running unloaded shutdown timer and cooling water solenoid valve control 1 (contact voltage 110 V/AC).
- Remote Control Package including the following digital functions.
- Operation contacts/commands: acknowledgement, reset, load/unload, start/stop.
- Remote contacts/indications: compressor ready, alarm/trip, running, remote status selected.
- Universal Communication Module (UCM) installed inside the CMC panel to provide remote command and communication. Supported standards or protocols include RS 232, Modicon's Modbus and Allen-Bradley DF1.