Air quality can have a significant impact on compressed air systems. Properly treated compressed air will improve productivity, system efficiency and product or process quality.
Choosing the appropriate dryers and filters is very important.
Ingersoll Rand has the widest selection of air treatment products and application knowledge to protect your investment and compressed air system.
Ranges:
5-001 High Inlet Temperature Refrigerated Dryers
(50 Hz) D25IT-A to D170IT-A
Flow Rate: From 0.4 To 2.4 m3/min
Max. Working Pressure: 14.5 bar g
Description
- CAir cooled / R134a / 3 in 1 Low Pressure Drop Aluminium Heat Exchanger
- Integrated general purpose filter removing air particle up to 1 micron
- Integrated aftercooler to handle inlet temperature up to 93 °C
- Electronic Drain as Standard
- Advanced Full Feature Control Panel with history of 10 alarms
- IP42 electrical rating
- Operating Limitations
- Ambient : Min 2ºC / Max 50ºC Air inlet temperature : Max 93º C
5-002 Refrigerant Dryer D-IN'
Flow Rate: From 0.2 To 212.9 m3/min " Air Cooled "
Pressure: From 12 To 14 bar g
Flow Rate: From 65.8 To 380 m3/min " Water ooled "
Pressure: From 12 To 14 bar g
Small Refrigerated Dryers (50 Hz) D12IN-A to D480IN-A
Description
- Air cooled / R134a / 3 in 1 Low Pressure Drop Aluminium Heat Exchanger
- Hermetically sealed piston refrigerant compressor / High Efficiency Condenser
- Variable Speed Fan, controlled by the Dryer Controller
- Electronic Drain as Standard
- Advanced Full Feature Control Panel with history of 10 alarms and remote alarm contact
- IP42 electrical rating
- Operating Limitations:Ambient : Min 2ºC / Max 50ºC Air inlet temperature : Max 60º C
Medium Refrigerated Dryers (50 Hz) D600IN-A to D5400IN-A
Description
- Air cooled / R507a / 3 in 1 Low Pressure Drop Aluminium Heat Exchanger
- Stainless Steel Demister / High Efficiency Condenser
- Anti-freezing/energy saving function
- Electronic No Loss Drain (ENLD) as Standard
- Advanced Control Panel with dew point indication and remote ON/OFF (From D1300IN-A)
- History of latest 10 alarms (D600IN-A to D950IN-A) and 50 alarms (D1300IN-A to D5400IN-A)
- Operating Limitations:
- Ambient : Min 2ºC / Max 50ºC (D600IN-A-D950IN-A) Air inlet temperature : Max 60º C
- Ambient : Min 2ºC / Max 45ºC (D1300IN-A-D5400IN-A)
Large Refrigerated Dryers (50 Hz) D4620IN-A to D22800IN-W
Description
- Air or water cooled / R407c / High efficiency scroll compressors
- Air-to-air exchanger (pre-cooler / re-heater) / Evaporator and water separator
- Electronic No Loss Drain (ENLD) as Standard
- Cataphoresis water manifold treatment
- Advanced Control Panel with dew point indication and automatic restart
- History of latest 50 alarms / Automatic Restart / Digital input for remote on / off
- Operating Limitations:
- Ambient : Min 2ºC / Max 46ºC Air inlet temperature : Max 65º C
- Water temperature: Min 20°C 1 / Max 45°C (water coo led models
5-003 Cycling Dryer TMS
Flow Rate: From 0.36 To 88 m3/min
Pressure: From 2 To 16 bar g
Thermal Mass™ Cycling Refrigerated Dryers (TMS 4 to TMS 38)
Description
- Air cooled / R134a / Hermetically sealed piston refrigerant compressor
- Thermal MassTM evaporator / Pre cooler and reheater (TMS 20 to TMS38)
- Integral float drain (TMS4 to TMS31) / ENLD (TMS38)
- Cyclone water separator included (loose:TMS4-TMS14)(Internally mounted:TMS20-TMS38)
- Instrumentation: Power on light / main switch
- Overheating & Current protection: Klixon thermal refrigeration compressor protection
- Operating Limitations:
- Ambient : Min 0ºC / Max 43ºC Air inlet temperature : Max 55º C
5-004 Modular Dryer D-IM
Flow Rate: From 5 To 299 m3/hr
Max. Pressure: From 12 To 16 bar
Modular Desiccant Dryers (D5IM to D299IM)
Description
- Air Quality to -40ºC ISO 8573 Class 2 dew point performance
- Optional ISO 8573 Class 1 dew point performance available
- Filtration Provided as Standard (Filters Shipped Loose on models D41IM and above)
- Electronic Control Panel:D5IM-D34IM Easy to Read User Interface/D41IM-D299IM Interface with Functionality, which also shows tower pressure gauges.
- Low noise levels for point of use application
- Operating Limitations:
- Ambient : Min 2ºC Air inlet temperature : Max 50º C
5-005 Desiccant Dryer D-IL and D-IB
Heatless Desiccant Dryers (D160IL to D3300IL)
Flow Rate: From 160 To 3,300 m3/hr
Pressure: From 7 To 10 bar
Description
- Inlet (High Efficiency) and outlet (General Purpose) heavy duty filters supplied with all dryers
- Control panel display: Tower status (drying & regeneration)/Operating & Purge Times/Operation Hours
- Alarms: High Dew Point (opt), fail to shift(opt), time of alarm, history of last 20 alarms
- Desiccant bed allows -40ºC (Std) and -70ºC (Optional) pressure dewpoint
- Energy Management System available as an option to reduce operating costs by measuring the outlet dewpoint and adjusting the cycle time accordingly to save energy
- Operating Limitations:
- Ambient : Min 1ºC / Max 50ºC Air inlet temperature : Max 50º C
Heated Blower Desiccant Dryers (D500IB to D14900IB)
Flow Rate: From 500 To 14,900 m3/hr
Pressure: From 7 To 10 bar
Description
- Inlet (High Efficiency) and outlet (General Purpose) heavy duty filters supplied with all dryers
- Control panel display: Tower status (drying & regeneration)/Operating & Purge Times/Operation Hours
- Alarm: High Dew Point, time of alarm, history of last 20 alarms, High Outlet Temperature, Blower failure
- Energy Management System available as std feature to reduce operating costs by measuring the outlet dewpoint and adjusting the cycle time accordingly to save energy
- Operating Limitations:
- Ambient : Min 1ºC / Max 50ºC Air inlet temperature : Max 50º C
- Minimum capacity = 23% of dryer maximum capacity at reference conditions
5-006 AirFiltration
Flow Rate: From 0.58 To 520 m3/min
Pressure: 7 bar g
General Purpose Protection Filters - BSPT Connection
Description
- Air quality to ISO 8573.1:2001 / Class 3 Solid particulate / Class 3 oil
Image to fit inside this size of box - Particle removal down to 1 micron
All images to have the new logo - Maximum remaining oil aerosol content 0.6 mg/m3 content @ 21 C
- Operating Limitations:
- Maximum operating pressure 17 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
High Efficiency Filters - BSPT Connection
Description
- Air quality to ISO 8573.1:2001 / Class 2 Solid particulate / Class 2 oil
Image to fit inside this size of box - Particle removal down to 0.01 micron
All images to have the new logo - Maximum remaining oil aerosol content 0.01 mg/m3 content @ 21 C
- Operating Limitations:
- Maximum operating pressure 17 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
- Note: Precede H filters with equivalent model G filters
Dust Filters - BSPT Connection
Description
- Air quality to ISO 8573.1:2001 / Class 3 Solid particulate
Image to fit inside this size of box - Particle removal down to 1 micron
All images to have the new logo
- Operating Limitations:
- Maximum operating pressure 17 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
Activated Charcoal Filters - BSPT Connection
Description
- Air quality to ISO 8573.1:2001 / Class 1 oil
Image to fit inside this size of box - Oil vapour and odour removal
All images to have the new logo - Maximum remaining oil vapour content <0.003 mg/m³ content @ 21 C
- Operating Limitations:
- Maximum operating pressure 17 bar (g)
- Maximum operating temperature 30 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
General Purpose Protection Filters - Flanges Connection
Description
- Air quality to ISO 8573.1:2001 / Class 3 Solid particulate / Class 3 oil
- Particle removal down to 1 micron
- Maximum remaining oil aerosol content 0.6 mg/m3 content @ 21 C
- Operating Limitations:
- Maximum operating pressure 16 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
High Efficiency Filters - Flanges Connection
Description
- Air quality to ISO 8573.1:2001 / Class 2 Solid particulate / Class 2 oil
- Particle removal down to 0.01 micron
- Maximum remaining oil aerosol content 0.01 mg/m3 content @ 21 C
- Operating Limitations:
- Maximum operating pressure 16 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
Dust Filters - Flanges Connection
Description
- Air quality to ISO 8573.1:2001 / Class 3 Solid particulate
- Particle removal down to 1 micron
- Operating Limitations
- Maximum operating pressure 16 bar (g)
- Maximum operating temperature 80 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
Activated Charcoal Filters - Flanges Connection
Description
- Air quality to ISO 8573.1:2001 / Class 1 oil
- Oil vapour and odour removal
- Maximum remaining oil vapour content <0.003 mg/m³ content @ 21 C
- Operating Limitations
- Maximum operating pressure 16 bar (g)
- Maximum operating temperature 30 C
- Minimum operating temperature 1 C
- Compliance with PED 97/23/EC and CE
5-007 Aftercoolers AC and WC
Flow Rate : From 0.6 To 75 m3/min " Air Cooled "
Pressure : From 9 To 16 bar g
Flow Rate : From 1.2 To 550 m3/min " Water ooled "
Pressure : From 10 To 16 bar g
Electric Air cooled Aftercoolers (ABC-6 to ABC-750)
Description
- Air cooled / Electric fan motor / Copper tubes aluminium fins
- High efficiency water separator with threaded connection / Automatic float drain / Support legs / Mounted thermometer (ABC180-ABC750)
- 50 Hz and 60 Hz models available for all models
- Electrical protection: IP44 (ABC6 to ABC12 and ABC25A to ABC35A) / IP54 (ABC25 to ABC360) / IP55 (ABC400 to ABC750)
- Operating Limitations:
- Ambient : Min 2ºC Air inlet temperature : Max 150º C
Pneumatic Air cooled Aftercoolers (ABC-35P to ABC-750P)
Description
- Air cooled / Pneumatic motor drive / Copper tubes aluminium fins
- High efficiency water separator with threaded connection / Automatic float drain / Support legs / Mounted thermometer (ABC180-ABC750)
- 50 Hz and 60 Hz models available for all models
- Electrical protection: IP44 (ABC6 to ABC12 and ABC25A to ABC35A) / IP54 (ABC25 to ABC360) / IP55 (ABC400 to ABC750)
- Operating Limitations:
- Ambient : Min 2ºC Air inlet temperature : Max 150º C
Water Cooled Aftercoolers-Fixed Tube Bundle (WBC-12 to WBC-900)
Description
- Water cooled with fixed cooling tubes / Shell and tube Heat exchanger
- Treated carbon steel vessel, copper tubes, aluminium baffles / High efficiency water separator
- Automatic float drain/Mounted thermometer & Counter flanges (from WBC 180)
- FH/V = Fixed cooler Horizontal or vertical and FH = Fixed cooler Horizontal only
- WBC-12 FH/V to 135 FH/V: factory assembled as horizontal versions, but include a separator connection elbow kit to convert to a vertical version as std
- Operating Limitations:
- Ambient : Min 2ºC Air inlet temperature : Max 200º C
- Inlet water temperature: Max 90ºC
Water Cooled Aftercooler - Removable Tube Bundle (WBC-30 to WBC-5500)
Description
- Water cooled with removable cooling tubes / Shell and tube Heat exchanger
- Treated carbon steel vessel, copper tubes, aluminium baffles / High efficiency water separator
- Automatic float drain/Mounted thermometer & Counter flanges (from WBC 220)
- RH/V=Removable cooler horizontal or vertical&RH=Removable cooler Horizontal only
- WBC-30 RH/V to 135 RH/V: factory assembled as horizontal versions, but include a separator connection elbow kit to convert to a vertical version as std
- Operating Limitations:
- Ambient : Min 2ºC Air inlet temperature : Max 200º C
- Inlet water temperature: Max 90ºC